请选择需要导出的字段:
ASTM C1057-2003(2010)
Standard Practice for Determination of Skin Contact Temperature from Heated Surfaces Using a Mathematical Model and Thermesthesiometer
适用范围:<p>The procedures in this practice support the determination of the burn hazard potential for a heated surface. These procedures provide an estimate of the maximum skin contact temperature and must be used in conjunction with Guide <a href="http://myastm.astm.org/SUBSCRIPTION/NewValidateSubscription.cgi?C1055-HTML">C1055</a> to evaluate the surface hazard potential.</p> <p>The two procedures outlined herein are both based upon the same heat transfer principles. Method A uses a mathematical model to predict the contact temperature, while Method B uses a plastic rubber probe having similar heat transfer characteristics to the human finger to <span class=''unicode''>x201C;</span>measure<span class=''unicode''>x201D;</span> the contact temperature on real systems.</p> <p>These procedures serve as an estimate for the skin contact temperatures which might occur for the <span class=''unicode''>x201C;</span>average<span class=''unicode''>x201D;</span> individual. Unusual conditions of exposure, incorrect design assumptions, subject health conditions, or unforeseen operating conditions may negate the validity of the estimations.</p> <p>These procedures are limited to direct contact exposure only. Conditions of personal exposure to periods of high ambient temperatures, direct flame exposure, or high radiant fluxes may cause human injury in periods other than determined herein. Evaluation of exposures other than direct contact are beyond the scope of this practice.</p> <p><span class="italic"><span class="italic">Cold Surface Exposure</span>8212;</span>No consensus criteria exists for the destruction of skin cells by freezing. If, at some future time, such criteria are developed, extrapolation of the techniques presented here will serve as a basis for cold surface exposure evaluation.</p><p id="s00002">1.1 This practice covers a procedure for evaluating the skin contact temperature for heated surfaces. Two complimentary procedures are presented. The first is a purely mathematical approximation that can be used during design or for worst case evaluation. The second method describes the thermesthesiometer, an instrument that analogues the human sensory mechanism and can be used only on operating systems. <p class="desc" id="N00001"> <span class="smallcap">Note</span> 18212;Both procedures listed herein are intended for use with Guide <a href="http://myastm.astm.org/SUBSCRIPTION/NewValidateSubscription.cgi?C1055-HTML">C1055</a>. When used in conjunction with that guide, these procedures can determine the burn hazard potential for a heated surface.</p> </p> <p id="s00003">1.2 A bibliography of human burn evaluation studies and surface hazard measurement is provided in the References at the end of Guide <a href="http://myastm.astm.org/SUBSCRIPTION/NewValidateSubscription.cgi?C1055-HTML">C1055</a>. Thermesthesiometer and mathematical modeling references are provided in the References at the end of this practice <span class="bold">(1-5)</span>. </p> <p id="s00301">1.3 This practice addresses the skin contact temperature determination for passive heated surfaces only. The analysis procedures contained herein are not applicable to chemical, electrical, or other similar hazards that provide a heat generation source at the location of contact.</p> <p id="s00300">1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.</p> <p id="s00004">1.5 <span class="italic">This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.</span>
实施日期: 2003-10-01
中标分类号: C78 - 医药、卫生、劳动保护 - 安全卫生管理
ICS分类号: 13.100 - 环境和保健、安全 - 职业安全、工业卫生
标准组织: ASTM - 美国材料与试验协会标准
全文来源: WF
英文关键词: burn potential elevated temperature health hazards in situ measurement maximum temperature temperature test thermothesiometer thermal contact Burn hazard potential Burning characteristics--thermal insulation Contact burning injuries Dermal exposure First degree burn Heated surfaces Heating tests Heating tests--thermal insulation Hyperthermia Injury Mathematical models/modeling Necrosis Physiological mechanisms of burns Second degree burn Skin Skin contact temperature Surface temperature (for burns) Temperature tests--thermal insulation Thermesthesiometer Third degree burn
语种: 汉语
页数: 6
知识产权声明 | 服务承诺 | 联系我们 | 客户服务 | 关于我们
互联网出版许可证:新出网证(京)字042号 互联网药品信息服务资格证书号:(京)-经营性-2011-0017 信息网络传播视听节目许可证 许可证号:0108284
万方数据标准管理系统V1.0 证书号:软著登字第4252816号
京ICP证:010071 京公网安备11010802020237号 京ICP备08100800号-1
客服电话:4000115888 客服邮箱:service@wanfangdata.com.cn 违法和不良信息举报电话:4000115888 举报邮箱:problem@wanfangdata.com.cn 举报专区:https://www.12377.cn
万方数据知识服务平台--国家科技支撑计划资助项目(编号:2006BAH03B01)©北京万方数据股份有限公司 万方数据电子出版社