请选择需要导出的字段:
ASTM C1136-2010
Standard Specification for Flexible,Low Permeance Vapor Retarders for Thermal Insulation
适用范围:<p>Entrapment of water in thermal insulation caused by condensation of water vapor that has penetrated into the insulation is detrimental to the thermal resistance of the insulation. For this reason, in certain installations where temperature and moisture conditions have the potential to create a vapor driving force toward the insulation, a deterrent to the passage of such vapor into the installed insulation needs to be provided. This is the primary function of the vapor retarder.</p> <p>In addition to the function stated in 9.1, a vapor retarder has the potential to provide physical protection and added strength to the insulation system.</p> <p>This specification is used to specify material by physical property requirements that address the above prerequisites. The designer of an insulation system, after determining the degree of protection needed for the insulation, can use this specification to specify the appropriate type of vapor retarder when one is required.</p><p id="s00002">1.1 This specification covers vapor retarders for thermal insulation, specifically, flexible materials with permeance of 0.10 perm or lower and surface burning characteristics of 25 flame spread/50 smoke or lower. These materials are intended for use at surface temperatures of <span class=''unicode''>x2212;</span>20 to 150<span class=''unicode''>x00B0;</span>F (<span class=''unicode''>x2212;</span>29 to 66<span class=''unicode''>x00B0;</span>C). It does not cover mastics or barrier coatings applied in liquid form, nor materials intended for use as weather barriers. </p> <p>1.2 This is a material specification and does not imply that an installed system using these materials will provide the physical properties specified in Section 6.</p> <p id="s00003">1.3 This specification provides physical requirements for vapor retarders. Practice <a href="http://myastm.astm.org/SUBSCRIPTION/NewValidateSubscription.cgi?C755-HTML">C755</a> provides assistance in solving problems related to moisture vapor transmission through thermal insulation materials.</p> <p id="s00004">1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.</p> <p id="s00005">1.5 <span class="italic"><span class="med">The following precautionary caveat pertains to the test methods portion only, Section 10, of this specification: </span><span class="italic">This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. </span></span>
实施日期: 2010-05-01
中标分类号: Q25 - 建材 - 绝热、吸声、轻质与防火材料
ICS分类号: 91.100.60 - 建筑材料和建筑物
标准组织: ASTM - 美国材料与试验协会标准
全文来源: WF
英文关键词: flexible low permeance thermal insulation vapor retarders Condensation Flammability--building materials Humidity Low-temperature service applications Puncture testing Thermal insulating materials--specifications Thermal insulating materials (water vapor transmission) Vapor barriers--specifications Water entrapment Water vapor retarders--specifications Water vapor transmission (WVT)--thermal insulation
语种: 汉语
页数: 4
知识产权声明 | 服务承诺 | 联系我们 | 客户服务 | 关于我们
网络出版服务许可证:(署)网出证(京)字第072号 互联网药品信息服务资格证书号:(京)-经营性-2016-0015 信息网络传播视听节目许可证 许可证号:0108284
万方数据标准管理系统V2.0 证书号:软著登字第11198474号
京ICP证:010071 京公网安备11010802020237号 京ICP备08100800号-1
客服电话:4000115888 客服邮箱:service@wanfangdata.com.cn 违法和不良信息举报电话:4000115888 举报邮箱:problem@wanfangdata.com.cn 举报专区:https://www.12377.cn
万方数据知识服务平台--国家科技支撑计划资助项目(编号:2006BAH03B01)©北京万方数据股份有限公司 万方数据电子出版社