请选择需要导出的字段:
ASTM C1309-1997(2003)
Standard Practice for Performance Evaluation of In-Plant Walk-Through Metal Detectors
适用范围:<p id="s00070">Walk-through metal detectors are an effective and unobtrusive means for searching for concealed metallic weapons and SNM (special nuclear material) shielding material. The detectors are generally applied to prevent the unauthorized entry of weapons into facilities, and theft or unauthorized removal of SNM. Daily functional testing of metal detectors shows that they are operating and will produce the correct alarm signal; the significant use of less frequent in-plant evaluations provides data from which to determine if detectors are operating at expected performance levels.</p> <p id="s00071">This practice provides a system of procedures for evaluating the detection performance of walk-through metal detectors.</p> <p id="s00072">The procedures specify data to be recorded and used for establishing, tracking, and auditing metal detector performance and operation.</p> <p id="s00073">This practice suggests documentation for maintaining performance records. <a href="ap00009">Appendix X4</a> provides examples of forms for recording and tracking detector operation and performance testing.</p><p>1.1 This practice is one of several (see Appendix X1) developed to assist operators of nuclear facilities with meeting the metal detection performance requirements set by regulatory authorities.</p><p>1.2 This practice consists of four procedures useful for evaluating the in-plant performance of walk-through metal detectors (see Fig. 1).</p><p>1.2.1 Two of the procedures provide data for evaluating probability of detection. These procedures use binomial data (alarm/not alarm).</p><p>1.2.1.1 The detection sensitivity test (DST)178; is the initial procedure in the detection probability evaluation series. It is used to establish the probability of detection immediately after the detector has been adjusted to its operational sensitivity setting.</p><p>1.2.1.2 The detection sensitivity verification test (DSVT)178; procedure periodically provides data for evaluation of continuing detection performance.</p><p>1.2.2 The third procedure is a "functional test." It is used routinely to verify that a metal detector is operating and responds with the correct audio and visual signals when subjected to a condition that should cause an alarm.</p><p>1.2.3 The fourth procedure is used to verify that alarms generated during detection sensitivity testing were likely the result of the detection of metal and not caused by outside interferences or the perturbation of the detection field by the tester''s body mass.</p><p>1.2.3.1 This procedure also can be used to establish a probability of occurrence for false alarms, for example, 20 test passes by a clean-tester resulting in no alarms indicates a false alarm probability of less than 0.15 at 95 % confidence. This procedure is optional unless required by the regulatory authority.</p><p>1.3 This practice does not set test object specifications. The specifications should be issued by the regulatory authority.</p><p>1.4 This practice is intended neither to set performance levels nor to limit or constrain technologies.</p><p>1.5 This practice does not address safety or operational issues associated with the use of walk-through metal detectors.</p>
知识产权声明 | 服务承诺 | 联系我们 | 客户服务 | 关于我们
网络出版服务许可证:(署)网出证(京)字第072号 互联网药品信息服务资格证书号:(京)-经营性-2016-0015 信息网络传播视听节目许可证 许可证号:0108284
万方数据标准管理系统V2.0 证书号:软著登字第11198474号
京ICP证:010071 京公网安备11010802020237号 京ICP备08100800号-1
客服电话:4000115888 客服邮箱:service@wanfangdata.com.cn 违法和不良信息举报电话:4000115888 举报邮箱:problem@wanfangdata.com.cn 举报专区:https://www.12377.cn
万方数据知识服务平台--国家科技支撑计划资助项目(编号:2006BAH03B01)©北京万方数据股份有限公司 万方数据电子出版社