查看标准

请选择需要导出的字段:

ASTM C1379-2010

用感应耦合等离子体质谱仪分析尿液中铀-235和铀-238同位素的试验方法

Standard Test Method for Analysis of Urine for Uranium-235 and Uranium-238 Isotopes by Inductively Coupled Plasma-Mass Spectrometry

适用范围:<p>DOE Order 5480.11 and ANSI N13.30 require that internal dose assessments be made as part of the bioassay program for nuclear facility workers. For indirect bioassay of uranium workers, the uranium isotopes must be measured along with the total uranium in urine samples. The RMDA for each uranium isotope is 0.1 pCi/L.</p> <p>This method is applicable for measuring <sup> 235</sup>U and <sup> 238</sup>U at the RMDA. Because of extremely low mass concentration (because of the high specific activity), <sup>234</sup>U cannot be measured without additional sample preconcentration.</p> <p class="desc" id="N00002"> <span class="smallcap">Note</span> 28212;Column chromatography separations and concentration of <sup> 234</sup>U using manual or flow-injection preconcentration followed by ICP-MS isotopic determination are described in Test Methods <a href="http://myastm.astm.org/SUBSCRIPTION/NewValidateSubscription.cgi?C1310-HTML">C1310</a> and <a href="http://myastm.astm.org/SUBSCRIPTION/NewValidateSubscription.cgi?C1345-HTML">C1345</a>. These methods focus on environmental soil sample analysis, but with some development, may be applicable to digested urine samples. The <sup> 234</sup>U concentration can be calculated based on an enrichment gradient for workers in uranium enrichment plants, and internal dose assessments can be made.</p> <p class="desc" id="N00030"> <span class="smallcap">Note</span> 38212;Use of high resolution ICP-MS may also be used to obtain lower detection limits. </p><p id="s00002">1.1 This test method covers the determination of the concentration of uranium-235 and uranium-238 in urine using Inductively Coupled Plasma-Mass Spectrometry. This test method can be used to support uranium facility bioassay programs.</p> <p id="s00003">1.2 This method detection limits for <sup> 235</sup>U and <sup> 238</sup>U are 6 ng/L. To meet the requirements of ANSI N13.30, the minimum detectable activity (MDA) of each radionuclide measured must be at least 0.1 pCi/L (0.0037 Bq/L). The MDA translates to 47 ng/L for <sup> 235</sup>U and 300 ng/L for <sup> 238</sup>U. Uranium<span class=''unicode''>x2013;</span> 234 cannot be determined at the MDA with this test method because of its low mass concentration level equivalent to 0.1 pCi/L. </p> <p id="s00004">1.3 The digestion and anion separation of urine may not be necessary when uranium concentrations of more than 100 ng/L are present.</p> <p id="s00778">1.4 <span class="italic"><span class="italic">Units</span>8212;</span>The values stated in picoCurie per liter units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.</p> <p id="s00005">1.5 <span class="italic">This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. <p class="desc" id="N00001"> <span class="smallcap">Note</span> 18212;<b>Warning: </b>The ICP-MS is a source of intense ultraviolet radiation from the radio frequency induced plasma. Protection from radio frequency radiation and UV radiation is provided by the instrument under normal operation.</p> </span>

实施日期: 2010-01-01

中标分类号: C44 - 医药、卫生、劳动保护 - 医用化验设备

ICS分类号: 11.100 - 医药卫生技术 - 实验室医学

标准组织: ASTM - 美国材料与试验协会标准

全文来源: WF

英文关键词: bioassay inductively coupled plasma-mass spectrometry total uranium concentration urine analysis ICP-MS (inductively-coupled plasma-mass spectrometry) Mass spectrometry--nuclear materials/applications Uranium concentration Uranium oxide (U<inf>3</inf>O<inf>8</inf>) Urinalysis

语种: 汉语

页数: 5

标准解读