请选择需要导出的字段:
ASTM D6160-1998(2008)
Standard Test Method for Determination of Polychlorinated Biphenyls (PCBs) in Waste Materials by Gas Chromatography
适用范围:<p>This test method provides sufficient PCB data for many regulatory requirements. While the most common regulatory level is 50 ppm (dry weight corrected), lower limits are used in some locations. Since sensitivities will vary for different types of samples, one shall demonstrate a sufficient method detection limit for the matrix of interest.</p> <p>This test method differs from Test Method D 4059<astmref rid="a00001"> in that it provides for more sample clean-up options, utilizes a capillary column for better pattern recognition and interference discrimination, and includes both a qualitative screening and a quantitative results option. </p><p id="s00002">1.1 This test method covers a two-tiered analytical approach to PCB screening and quantitation of liquid and solid wastes, such as oils, sludges, aqueous solutions, and other waste matrices. </p> <p id="s00003">1.2 Tier I is designed to screen samples rapidly for the presence of PCBs.</p> <p id="s00004">1.3 Tier II is used to determine the concentration of PCBs, typically in the range of from 2 to 50 mg/kg. PCB concentrations greater than 50 mg/kg are determined through analysis of sample dilutions. </p> <p id="s00005">1.4 This is a pattern recognition approach, which does <span class="italic">not</span> take into account individual congeners that might occur, such as in reaction by-products. This test method describes the use of Aroclors 1016, 1221, 1232, 1242, 1248, 1254, 1260, 1262, and 1268, as reference standards, but others could also be included. Aroclors 1016 and 1242 have similar capillary gas chromatography (GC) patterns. Interferences or weathering are especially problematic with Aroclors 1016, 1232, and 1242 and may make distinction between the three difficult.</p> <p id="s00006">1.5 This test method provides sample clean up and instrumental conditions necessary for the determination of Aroclors. Gas chromatography (GC) using capillary column separation technique and electron capture detector (ECD) are described. Other detectors, such as atomic emission detector (AED) and mass spectrometry (MS), may be used if sufficient performance (for example, sensitivity) is demonstrated. Further details about the use of GC and ECD are provided in Practices E 355<astmref rid="a00005">, E 697<astmref rid="a00006">, and E 1510<astmref rid="a00007">.</p> <p id="s00007">1.6 Quantitative results are reported on the dry weights of waste samples.</p> <p id="s00008">1.7 Quantification limits will vary depending on the type of waste stream being analyzed.</p> <p>1.8 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.</p> <p id="s00009">1.9 <span class="italic">This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulator limitations prior to use.</span>
实施日期: 1998-11-10
中标分类号: Z13 - 环境保护 - 固体废弃物、土壤及其他环境要素采样方法
ICS分类号: 13.030.30 - 环境和保健、安全 - 特殊废物
标准组织: ASTM - 美国材料与试验协会标准
全文来源: WF
英文关键词: gas chromatography GC/ECD PCBs polychlorinated biphenyls Gas chromatography (GC)--petroleum products PCBs (polychlorinated biphenyls) Waste materials/processing/analysis
语种: 汉语
页数: 14
知识产权声明 | 服务承诺 | 联系我们 | 客户服务 | 关于我们
网络出版服务许可证:(署)网出证(京)字第072号 互联网药品信息服务资格证书号:(京)-经营性-2016-0015 信息网络传播视听节目许可证 许可证号:0108284
万方数据标准管理系统V2.0 证书号:软著登字第11198474号
京ICP证:010071 京公网安备11010802020237号 京ICP备08100800号-1
客服电话:4000115888 客服邮箱:service@wanfangdata.com.cn 违法和不良信息举报电话:4000115888 举报邮箱:problem@wanfangdata.com.cn 举报专区:https://www.12377.cn
万方数据知识服务平台--国家科技支撑计划资助项目(编号:2006BAH03B01)©北京万方数据股份有限公司 万方数据电子出版社