ASTM D7053/D7053M-2011
Standard Guide for Determining and Evaluating Causes of Water Leakage of Low-Sloped Roofs
适用范围:<p>This guide is intended to provide building professionals with a methodology for evaluating water leakage through low-sloped roofs. It addresses the service history of a roof, the various components of a roof, and the interaction between these components and adjacent construction. It is not intended as a construction quality control procedure, as specified in Practice <a href="http://myastm.astm.org/SUBSCRIPTION/NewValidateSubscription.cgi?D7186-HTML">D7186</a>, nor as a preconstruction qualification procedure. It is intended for evaluating water leakage through a low-sloped roof.</p> <p><span class="italic"><span class="italic">Qualifications</span>8212;</span>Use of this guide requires a background as an architect, engineer, roof/waterproofing consultant, roofing contractor, or related profession with an understanding in building construction and the expertise in the design, installation, and maintenance of low-sloped roofs.</p> <p><span class="italic"><span class="italic">Application</span>8212;</span>The sequential activities described herein are intended to produce an evaluation program, but all activities may not be applicable or necessary for a particular evaluation program. It is the responsibility of the professional using this guide to determine the activities and sequence necessary to perform an appropriate leakage evaluation for a specific low-sloped roof on a building.</p> <p><span class="italic"><span class="italic">Preliminary Assessment</span>8212;</span>A preliminary assessment may indicate that water leakage problems are limited to a specific element or portion of a low-sloped roof. The evaluation of causes may be limited in scope, and the procedures recommended herein abridged according to the professional judgment of the investigator. A statement stipulating the limits of the investigation should be included in the report.</p> <p><span class="italic"><span class="italic">Expectations</span>8212;</span>Expectations about the overall effectiveness of an evaluation program must be reasonable, and in proportion to a defined scope of work. This guide is intended to address leakage of a low-sloped roof system, leading to conclusions that can generally be applied to similar or other locations on the roof. Since every possible location is not included in an evaluation program, it is probable that every leak source will not be identified. Leak sources that are localized and unique may remain, and require specific and localized evaluation effort. </p> <p>This guide is not intended as a design guide. Reference is made to design features of a low-sloped roof only for the purpose of identifying items of interest for consideration in the evaluation process.</p> <p>This guide does not address leakage through walls not associated with roof construction, fenestration, or leakage below-grade. It is not intended for use with structures designed to retain water, such as pools, fountains, and vegetative roofs. </p><p id="s00002">1.1 This guide describes methods for determining and evaluating causes of water leakage in low-sloped roofs. For this purpose, water penetration is considered leakage and therefore problematic, is causing or is likely to cause premature deterioration of the roof, building or its contents, or is adversely affecting the performance of other components of the building A roof is considered an assembly including the membrane, insulation, vapor retarder (if required), deck, and structural components. </p> <p id="s00100">1.1.1 This guide excludes moisture-related problems in roofs caused by condensation.</p> <p class="desc" id="N00001"> <span class="smallcap">Note</span> 18212;<span class="italic">Condensation</span><char: emdash>Moisture-related problems in roof systems may be caused by condensation of humid air originating from within the building and be incorrectly attributed to leakage from rain water. The protocol for an investigation of dampness due to condensation and is c......
实施日期: 2011-05-01
标准组织: ASTM - 美国材料与试验协会标准
全文来源: WF
英文关键词: evaluation inspection leaks low-sloped roof roof testing water leakage Low-sloped roofs Roofing membranes
语种: 汉语
页数: 8
知识产权声明 | 服务承诺 | 联系我们 | 客户服务 | 关于我们
网络出版服务许可证:(署)网出证(京)字第072号 互联网药品信息服务资格证书号:(京)-经营性-2016-0015 信息网络传播视听节目许可证 许可证号:0108284
万方数据标准管理系统V2.0 证书号:软著登字第11198474号
京ICP证:010071 京公网安备11010802020237号 京ICP备08100800号-1
客服电话:4000115888 客服邮箱:service@wanfangdata.com.cn 违法和不良信息举报电话:4000115888 举报邮箱:problem@wanfangdata.com.cn 举报专区:https://www.12377.cn
万方数据知识服务平台--国家科技支撑计划资助项目(编号:2006BAH03B01)©北京万方数据股份有限公司 万方数据电子出版社