请选择需要导出的字段:
ASTM D7706-2011
Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers
适用范围:<p>Manufacturers increasingly are being asked or required to demonstrate that vapor-phase emissions of chemicals of concern from their products under normal use conditions comply with various voluntary or regulatory acceptance criteria. This process typically requires manufacturers to have their products periodically tested for VOC emissions by independent laboratories using designated reference test methods (for example, Test Method <a href="http://myastm.astm.org/SUBSCRIPTION/NewValidateSubscription.cgi?D6007-HTML">D6007</a>, ISO 16000-9, and ISO 16000-10). To ensure continuing compliance, manufacturers may opt to, or be required to, implement screening tests at the production level.</p> <p>Reference methods for testing chemical emissions from products are rigorous and typically are too time-consuming and impractical for routine emission screening in a production environment.</p> <p>Micro-scale chambers are unique in that their small size and operation at moderately elevated temperatures facilitate rapid equilibration and shortened testing times. Provided a sufficiently repeatable correlation with reference test results can be demonstrated, appropriate control levels can be established and micro-scale chamber data can be used to monitor product manufacturing for likely compliance with reference acceptance criteria. Enhanced turnaround time for results allows for more timely adjustment of parameters to maintain consistent production with respect to vapor-phase chemical emissions.</p> <p>This practice can also be used to monitor the quality of raw materials for manufacturing processes.</p> <p>The use of elevated temperatures additionally facilitates screening tests for emissions of semi-volatile VOCs (SVOCs) such as some phthalate esters and other plasticizers.</p><p id="s00002">1.1 This practice describes a micro-scale chamber apparatus and associated procedures for rapidly screening materials and products for their vapor-phase emissions of volatile organic compounds (VOCs) including formaldehyde and other carbonyl compounds. It is intended to complement, not replace reference methods for measuring chemical emissions for example, small-scale chamber tests (Guide <a href="http://myastm.astm.org/SUBSCRIPTION/NewValidateSubscription.cgi?D5116-HTML">D5116</a>) and emission cell tests (Practice <a href="http://myastm.astm.org/SUBSCRIPTION/NewValidateSubscription.cgi?D7143-HTML">D7143</a>).</p> <p id="s00003">1.2 This practice is suitable for use in and outside of laboratories, in manufacturing sites and in field locations with access to electrical power.</p> <p id="s00004">1.3 Compatible material/product types that may be tested in the micro-scale chamber apparatus include rigid materials, dried or cured paints and coatings, compressible products, and small, irregularly-shaped components such as polymer beads.</p> <p id="s00005">1.4 This practice describes tests to correlate emission results obtained from the micro-scale chamber with results obtained from VOC emission reference methods (for example, Guide <a href="http://myastm.astm.org/SUBSCRIPTION/NewValidateSubscription.cgi?D5116-HTML">D5116</a>, Test Method <a href="http://myastm.astm.org/SUBSCRIPTION/NewValidateSubscription.cgi?D6007-HTML">D6007</a>, Practice <a href="http://myastm.astm.org/SUBSCRIPTION/NewValidateSubscription.cgi?D7143-HTML">D7143</a>, and ISO 16000-9 and ISO 16000-10).</p> <p id="s00006">1.5 The micro-scale chamber apparatus operates at moderately elevated temperatures, 30<span class=''unicode''>x00B0;</span>C to 60<span class=''unicode''>x00B0;</span>C, to eliminate the need for cooling, to reduce test times, boost emission rates, and enhance analytical signals for routine emission screening, and to facilitate screening of semi-volatile VOC (SVOC) emissions such as emissions of some phthalate esters and other plasticizers.</p> <p id="s00007">1.6 Gas sample collection and chemical analysis are dependent upon the nature of the VOCs targeted......
实施日期: 2011-03-01
标准组织: ASTM - 美国材料与试验协会标准
全文来源: WF
英文关键词: emissions formaldehyde indoor air quality semi-volatile organic compounds volatile organic compounds
语种: 汉语
页数: 9
知识产权声明 | 服务承诺 | 联系我们 | 客户服务 | 关于我们
网络出版服务许可证:(署)网出证(京)字第072号 互联网药品信息服务资格证书号:(京)-经营性-2016-0015 信息网络传播视听节目许可证 许可证号:0108284
万方数据标准管理系统V2.0 证书号:软著登字第11198474号
京ICP证:010071 京公网安备11010802020237号 京ICP备08100800号-1
客服电话:4000115888 客服邮箱:service@wanfangdata.com.cn 违法和不良信息举报电话:4000115888 举报邮箱:problem@wanfangdata.com.cn 举报专区:https://www.12377.cn
万方数据知识服务平台--国家科技支撑计划资助项目(编号:2006BAH03B01)©北京万方数据股份有限公司 万方数据电子出版社