查看标准

请选择需要导出的字段:

ASTM E1250-1988(2005)

用电离室评定用于测试硅电子装置辐射强度的钴60辐照器低能伽玛部件的试验方法

Standard Test Method for Application of Ionization Chambers to Assess the Low Energy Gamma Component of Cobalt-60 Irradiators Used in Radiation-Hardness Testing of Silicon Electronic Devices

适用范围:<p id="s00016">Although Co-60 nuclei only emit monoenergetic gamma rays at 1.17 and 1.33 MeV, the finite thickness of sources, and encapsulation materials and other surrounding structures that are inevitably present in irradiators can contribute a substantial amount of low-energy gamma radiation, principally by Compton scattering <span class="bold">(1, 2)</span>.<sup class="foot"><a href="fn00003">3</a></sup> In radiation-hardness testing of electronic devices this low-energy photon component of the gamma spectrum can introduce significant dosimetry errors for a device under test since the equilibrium absorbed dose as measured by a dosimeter can be quite different from the absorbed dose deposited in the device under test because of absorbed dose enhancement effects <span class="bold">(3, 4)</span>. Absorbed dose enhancement effects refer to the deviations from equilibrium absorbed dose caused by non-equilibrium electron transport near boundaries between dissimilar materials.</p> <p id="s00017">The ionization chamber technique described in this method provides an easy means for estimating the importance of the low-energy photon component of any given irradiator type and configuration.</p> <p id="s00018">When there is an appreciable low-energy spectral component present in a particular irradiator configuration, special experimental techniques should be used to ensure that dosimetry measurements adequately represent the absorbed dose in the device under test. (See Practice E 1249<astmref rid="a00003">.)</p><p>1.1 Low energy components in the photon energy spectrum of Co-60 irradiators lead to absorbed dose enhancement effects in the radiation-hardness testing of silicon electronic devices. These low energy components may lead to errors in determining the absorbed dose in a specific device under test. This method covers procedures for the use of a specialized ionization chamber to determine a figure of merit for the relative importance of such effects. It also gives the design and instructions for assembling this chamber.</p><p>1.2 This method is applicable to measurements in Co-60 radiation fields where the range of exposure rates is 7 10<sup> 6</sup> to 3 10<sup>2</sup> C kg<sup> 1</sup> s<sup>1</sup> (approximately 100 R/h to 100 R/s). For guidance in applying this method to radiation fields where the exposure rate is >100 R/s, see . Note 1See Terminology E 170 for definition of exposure and its units.</p></p><p>1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.</p><p>This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.</p>

实施日期: 1988-05-26

中标分类号: F80 - 能源、核技术 - 核仪器与探测器综合

ICS分类号: 31.020 - 电子学 - 电子元件综合

标准组织: ASTM - 美国材料与试验协会标准

全文来源: WF

中文关键词: 核能 电离 电子工程 电子仪器 硬度测量

语种: 汉语

页数: 11

· 您可以在购买后查看以下字段:
代替关系、替代关系
购买

标准解读