ASTM E1250-1988(2005)
Standard Test Method for Application of Ionization Chambers to Assess the Low Energy Gamma Component of Cobalt-60 Irradiators Used in Radiation-Hardness Testing of Silicon Electronic Devices
适用范围:<p id="s00016">Although Co-60 nuclei only emit monoenergetic gamma rays at 1.17 and 1.33 MeV, the finite thickness of sources, and encapsulation materials and other surrounding structures that are inevitably present in irradiators can contribute a substantial amount of low-energy gamma radiation, principally by Compton scattering <span class="bold">(1, 2)</span>.<sup class="foot"><a href="fn00003">3</a></sup> In radiation-hardness testing of electronic devices this low-energy photon component of the gamma spectrum can introduce significant dosimetry errors for a device under test since the equilibrium absorbed dose as measured by a dosimeter can be quite different from the absorbed dose deposited in the device under test because of absorbed dose enhancement effects <span class="bold">(3, 4)</span>. Absorbed dose enhancement effects refer to the deviations from equilibrium absorbed dose caused by non-equilibrium electron transport near boundaries between dissimilar materials.</p> <p id="s00017">The ionization chamber technique described in this method provides an easy means for estimating the importance of the low-energy photon component of any given irradiator type and configuration.</p> <p id="s00018">When there is an appreciable low-energy spectral component present in a particular irradiator configuration, special experimental techniques should be used to ensure that dosimetry measurements adequately represent the absorbed dose in the device under test. (See Practice E 1249<astmref rid="a00003">.)</p><p>1.1 Low energy components in the photon energy spectrum of Co-60 irradiators lead to absorbed dose enhancement effects in the radiation-hardness testing of silicon electronic devices. These low energy components may lead to errors in determining the absorbed dose in a specific device under test. This method covers procedures for the use of a specialized ionization chamber to determine a figure of merit for the relative importance of such effects. It also gives the design and instructions for assembling this chamber.</p><p>1.2 This method is applicable to measurements in Co-60 radiation fields where the range of exposure rates is 7 10<sup> 6</sup> to 3 10<sup>2</sup> C kg<sup> 1</sup> s<sup>1</sup> (approximately 100 R/h to 100 R/s). For guidance in applying this method to radiation fields where the exposure rate is >100 R/s, see . Note 1See Terminology E 170 for definition of exposure and its units.</p></p><p>1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.</p><p>This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.</p>
知识产权声明 | 服务承诺 | 联系我们 | 客户服务 | 关于我们
互联网出版许可证:新出网证(京)字042号 互联网药品信息服务资格证书号:(京)-经营性-2011-0017 信息网络传播视听节目许可证 许可证号:0108284
万方数据标准管理系统V1.0 证书号:软著登字第4252816号
京ICP证:010071 京公网安备11010802020237号 京ICP备08100800号-1
客服电话:4000115888 客服邮箱:service@wanfangdata.com.cn 违法和不良信息举报电话:4000115888 举报邮箱:problem@wanfangdata.com.cn 举报专区:https://www.12377.cn
万方数据知识服务平台--国家科技支撑计划资助项目(编号:2006BAH03B01)©北京万方数据股份有限公司 万方数据电子出版社