查看标准

请选择需要导出的字段:

ASTM E1680-1995(2003)

空气经金属外屋面板系统泄漏速度的试验方法

Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems

适用范围:<p>1.1 This test method covers the determination of the resistance of exterior metal roof panel systems to air infiltration resulting from either positive or negative air pressure differences. The test method described is for tests with constant temperature and humidity across the specimen. This test method is a specialized adaption of Test Method E 283.</p><p>1.2 This test method is applicable to any roof area. This test method is intended to measure only the air leakage associated with the field of the roof, including the panel side laps and structural connections; it does not include leakage at the openings or perimeter or any other details.</p><p>1.3 The proper use of this test method requires knowledge of the principles of air flow and pressure measurements.</p><p>1.4 The text of this test method references notes and footnotes excluding tables and figures, which provide explanatory material. These notes and footnotes shall not be considered to be requirements of the test method.</p><p>1.5 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.</p><p>1.6 <i>This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.</i> For specific precautionary statements, see Section 7.

实施日期: 1995-04-15

中标分类号: C32 - 医药、卫生、劳动保护 - 眼科与耳鼻咽喉科手术器械

ICS分类号: 91.060.20 - 建筑材料和建筑物 - 屋顶

标准组织: ASTM - 美国材料与试验协会标准

全文来源: WF

中文关键词: 建筑工程材料 端搭叠 外部金属屋面板系统 流量和流动速率 漏气速率 屋顶和防水材料 建筑结构材料 空气压力试验 热膨胀 外部应用 压力试验 漏泄试验 试验 材料 建筑工程 灰泥 流量计 墙板 板条

语种: 汉语

页数: 6

标准解读