请选择需要导出的字段:
BS EN 50065-2-3-2003
Signaluebertragung auf elektrischen Niederspannungsnetzen im Frequenzbereich 3 kHz bis 148,5 kHz. Stoerfestigkeitsanforderungen an Netz-Daten bertragungsgeraete und systeme die im Frequenzbereich 3 kHz bis 95 kHz betrieben werden und fuer den Gebrauch durch Stromversorgungs-und-verteilungsunternehmen bestimmt sind Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz. Part 2-3:Immunity requirements for mains communications equipment and systems operating in
适用范围:This standard applies to electrical equipment using signals in the frequency range 3 kHz to 95 kHz to transmit or receive information on low voltage electrical systems, for electricity suppliers and distributors. In the case of equipment which includes functions other than the transmission or reception of information on low voltage electrical supplies, this standard applies only to that part of the equipment intended for such transmission or reception of information. Other parts of the equipment shall comply with the immunity standard or standards relevant to the functions of those other parts. In the event of tests being specified in those other standards of a different severity and where the construction of the equipment is such that the functions cannot be tested separately, the higher severity shall apply to all affected functions. The object of this standard is to limit mutual influence between mains communication equipment and systems (MCES) operating in different frequency bands as defined in EN 50065-1 and to contribute to ensuring electromagnetic compatibility in general. It specifies essential immunity requirements and test methods, including those tests which are to be performed during type-testing of MCES on low-voltage installations, for electromagnetic interference in general and more specific interference coming from other MCES. It therefore defines the immunity test requirements for apparatus in relation to continuous and transient disturbances, both conducted and radiated, and electrostatic discharges. Test requirements are specified for each port considered. This standard gives limits which are applicable to products operating in the public supply network, operated by electricity utilities. The levels do not however cover extreme cases which may occur in any location but with a low probability of occurrence. In special cases situations will arise where the level of disturbances may exceed the levels specified in this standard e.g. where a hand-held transmitter is used in proximity to an apparatus. In these instances special mitigation measures may have to be employed. It does not specify immunity between mains communication systems operating in the same band (as defined in EN 50065-1) or immunity to signals originating from power line carrier systems operating on high or medium voltage networks. Safety considerations are not included in this standard.
知识产权声明 | 服务承诺 | 联系我们 | 客户服务 | 关于我们
互联网出版许可证:新出网证(京)字042号 互联网药品信息服务资格证书号:(京)-经营性-2011-0017 信息网络传播视听节目许可证 许可证号:0108284
万方数据标准管理系统V1.0 证书号:软著登字第4252816号
京ICP证:010071 京公网安备11010802020237号 京ICP备08100800号-1
客服电话:4000115888 客服邮箱:service@wanfangdata.com.cn 违法和不良信息举报电话:4000115888 举报邮箱:problem@wanfangdata.com.cn 举报专区:https://www.12377.cn
万方数据知识服务平台--国家科技支撑计划资助项目(编号:2006BAH03B01)©北京万方数据股份有限公司 万方数据电子出版社