BS EN 60904-7-2009
Photovoltaische Einrichtungen. Berechnung der spektralen Fehlanpassungskorrektion für Messungen an photovoltaischen Einrichtungen Photovoltaic devices. Part 7:Computation of the spectral mismatch correction for measurements of photovoltaic devices Dispositifs photovolta?ques. Calcul de la correction de désadaptation des réponses spectrales dans les mesures de dispositifs photovolta?ques
适用范围:This part of IEC 60904 describes the procedure for correcting the bias error introduced in thetesting of a photovoltaic device, caused by the mismatch between the test spectrum and thereference spectrum and by the mismatch between the spectral responses (SR) of thereference cell and of the test specimen. The procedure applies only to photovoltaic deviceslinear in SR as defined in IEC 60904-10. This procedure is valid for single junction devicesbut the principle may be extended to cover multijunction devices.The purpose of this standard is to give guidelines for the correction of measurement bias,should there be a mismatch between both the test spectrum and the reference spectrum andbetween the reference device SR and the test specimen SR.Since a PV device has a wavelength-dependent response, its performance is significantlyaffected by the spectral distribution of the incident radiation, which in natural sunlight varieswith several factors such as location, weather, time of year, time of day, orientation of thereceiving surface, etc., and with a simulator varies with its type and conditions. If theirradiance is measured with a thermopile-type radiometer (that is not spectrally selective) orwith a reference solar cell, the spectral irradiance distribution of the incoming light must beknown to make the necessary corrections to obtain the performance of the PV device underthe reference solar spectral distribution defined in IEC 60904-3.If a reference PV device or a thermopile type detector is used to measure the irradiance then,following the procedure given in this standard, it is possible to calculate the spectral mismatchcorrection necessary to obtain the short-circuit current of the test PV device under thereference solar spectral irradiance distribution included in Table 1 of IEC 60904-3 or anyother reference spectrum. If the reference PV device has the same relative spectral responseas the test PV device then the reference device automatically takes into account deviations ofthe real light spectral distribution from the standard spectral distribution, and no furthercorrection of spectral bias errors is necessary. In this case, location and weather conditionsare not critical when the reference device method is used for outdoor performancemeasurements provided both reference cell and test PV device have the same relativespectral response. Also, for identical relative SR’s, the spectral classification of the simulatoris not critical for indoor measurements.If the performance of a PV device is measured using a known spectral irradiance distribution,its short-circuit current at any other spectral irradiance distribution can be computed using thespectral response of the PV test device.
知识产权声明 | 服务承诺 | 联系我们 | 客户服务 | 关于我们
互联网出版许可证:新出网证(京)字042号 互联网药品信息服务资格证书号:(京)-经营性-2011-0017 信息网络传播视听节目许可证 许可证号:0108284
万方数据标准管理系统V1.0 证书号:软著登字第4252816号
京ICP证:010071 京公网安备11010802020237号 京ICP备08100800号-1
客服电话:4000115888 客服邮箱:service@wanfangdata.com.cn 违法和不良信息举报电话:4000115888 举报邮箱:problem@wanfangdata.com.cn 举报专区:https://www.12377.cn
万方数据知识服务平台--国家科技支撑计划资助项目(编号:2006BAH03B01)©北京万方数据股份有限公司 万方数据电子出版社